Babcock and Wilcox Boiler: Definition, Parts, Working, Advantages, Disadvantages, Applications [With PDF]

Introduction:

Babcock and Wilcox Boiler was discovered by George Herman Babcock and Stephen Wilcox in the year 1967. It is a water tube boiler, used in steam power plants. In this type of boiler, water is circulated inside the tubes and hot gases flow over the tubes. It is a Horizontal drum axis, natural draft, natural circulation, multitubular, stationary, high pressure, solid fuel fired, externally fired  Water tube boiler.

Parts of Babcock and Wilcox Boiler:

Following are the parts of a Babcock and Willcox Boiler:

  • Drum
  • Water Tubes
  • Uptake and Downtake header
  • Grate
  • furnace
  • Baffles
  • Superheater
  • Mud box
  • Inspection Door
  • Water Level Indicator
  • Pressure Gauge
Babcock and Wilcox Boiler diagram and parts

Drum:

It is a horizontal axis drum that contains water and steam.

Water tubes:

Water tubes are placed between the drum and furnace in an inclined position (at an angle of 10 to 15 degrees) to promote water circulation.

Uptake and Downtake Header:

This is present at the front end of the boiler and connected to the front end of the drum. It transports the steam from the water tubes to the drum. This is present at the rear end of the boiler and connects the water tubes to the rear end of the drum. It receives water from the drum.

Grate:

Coal is fed to the grate through the fire door.

Furnace:

The furnace is kept below the uptake header.

Baffles:

The fire-brick baffles, two in number, are provided to deflect the hot flue gases.

Superheater:

It increases the temperature of saturated steam to the required temperature before discharging it from the steam stop valve.

Mud Box:

This is used to collect the mud present in the water. A mud box is provided at the bottom end of the down-take header.

Inspection Door:

Inspection doors are provided for cleaning and inspection of the boiler.

Water Level Indicator:

The water level indicator shows the level of water within the drum.

Pressure Gauge:

The pressure gauge is used to check the pressure of steam within the boiler drum.

Working Principle of Babcock and Wilcox Boiler:

First the water starts to come in the water tubes from the drum with the help of a boiler feed pump which continues to feed the water against the drum pressure. The water present in the inclined water tubes gets heated up by the hot flue gases produced by the burning of coal on the fire grate. These fuel gases are uniformly heated in the water tube with the help of a baffle plate which works to deflect the flue gas uniformly throughout the tubes.

As the hot flue gases come in contact with water tubes, It exchanges the heat with the heater and converts it into steam. Continuous circulation of water from the drum to the water tubes and water tubes to the drum is thus maintained. The circulation of water is maintained by convective current and it’s known as Natural Circulation. The Steam generated is moved upward, due to density difference, and through the up-take header, it gets collected at the upper side of the boiler drum.

Anti-priming pipe is inside the drum which separates the moisture from the steam and sends it to the superheater. The superheater receives water-free steam from an anti-priming pipe. It increases the temperature of the steam to the desired level and transfers it to the main steam stop valve of the boiler. The superheated steam stop valve is either collected in a steam drum or sends it inside the steam turbine for electricity generation.

Applications Babcock and Wilcox Boiler:

The main application of Babcock and Wilcox boiler is to produce high-pressure steam in power generation industries.

Advantages of Babcock and Wilcox:

The advantages of Babcock and Wilcox boiler are:

  • The overall efficiency of this boiler is high.
  • The steam generation rate is higher about 20 tons per hour at a pressure of 10 to 20 bars.
  • The tubes can be replaced easily.
  • The boiler can expand and contract freely.
  • It is easy to repair, maintain and clean.

Disadvantages of Babcock and Wilcox Boiler:

Following are some disadvantages of Babcock and Wilcox Boiler:

  • It is less suitable for impure and sedimentary water, as a small deposit of scale may cause the overheating and bursting of tubes. Hence, water treatment is very essential for water tube boilers.
  • Failure in the feed water supply even for a short period is liable to overheat the boiler. Hence the water level must be watched very carefully during the operation of a water tube boiler.
  • The maintenance cost is high.

FAQ:

What is Babcock and Wilcox boiler?

Babcock And Wilcox boilers are a type of water tube boiler.

What are the different types of water tube boilers?

1. Loeffler boiler
2. Yarrow boiler.
3. Lamont Boiler
4. Babcock and Wilcox Boiler
5. Lamont Boiler
6. Benson Boiler

What are the advantages of Babcock And Wilcox Boiler?

1. The overall efficiency of this boiler is high.
2. The steam generation rate is higher at about 20 tons per hour at a pressure of 10 to 20 bars.
3. The tubes can be replaced easily.

What are the parts or construction of Babcock And Wilcox Boiler?

Drum
Water Tubes
Uptake and Downtake header
Grate
furnace
Baffles
Superheater
Mud box
Inspection Door
Water Level Indicator
Pressure Gauge

2 thoughts on “Babcock and Wilcox Boiler: Definition, Parts, Working, Advantages, Disadvantages, Applications [With PDF]”

Leave a Comment